Evtugyn GA

References (6)

Title : Acetylcholinesterase biosensor for inhibitor measurements based on glassy carbon electrode modified with carbon black and pillar[5]arene - Shamagsumova_2015_Talanta_144_559
Author(s) : Shamagsumova RV , Shurpik DN , Padnya PL , Stoikov, II , Evtugyn GA
Ref : Talanta , 144 :559 , 2015
Abstract : Shamagsumova_2015_Talanta_144_559
ESTHER : Shamagsumova_2015_Talanta_144_559
PubMedSearch : Shamagsumova_2015_Talanta_144_559
PubMedID: 26452862

Title : Cholinesterase sensor based on glassy carbon electrode modified with Ag nanoparticles decorated with macrocyclic ligands - Evtugyn_2014_Talanta_127_9
Author(s) : Evtugyn GA , Shamagsumova RV , Padnya PV , Stoikov II , Antipin IS
Ref : Talanta , 127 :9 , 2014
Abstract : Evtugyn_2014_Talanta_127_9
ESTHER : Evtugyn_2014_Talanta_127_9
PubMedSearch : Evtugyn_2014_Talanta_127_9
PubMedID: 24913851

Title : Acetylcholinesterase biosensor based on single-walled carbon nanotubes--Co phtalocyanine for organophosphorus pesticides detection - Ivanov_2011_Talanta_85_216
Author(s) : Ivanov AN , Younusov RR , Evtugyn GA , Arduini F , Moscone D , Palleschi G
Ref : Talanta , 85 :216 , 2011
Abstract : Ivanov_2011_Talanta_85_216
ESTHER : Ivanov_2011_Talanta_85_216
PubMedSearch : Ivanov_2011_Talanta_85_216
PubMedID: 21645691

Title : Bi-enzyme sensor based on thick-film carbon electrode modified with electropolymerized tyramine - Suprun_2004_Bioelectrochemistry_63_281
Author(s) : Suprun EV , Budnikov HC , Evtugyn GA , Brainina Kh Z
Ref : Bioelectrochemistry , 63 :281 , 2004
Abstract : Suprun_2004_Bioelectrochemistry_63_281
ESTHER : Suprun_2004_Bioelectrochemistry_63_281
PubMedSearch : Suprun_2004_Bioelectrochemistry_63_281
PubMedID: 15110288

Title : Polyaniline-modified cholinesterase sensor for pesticide determination - Ivanov_2002_Bioelectrochemistry_55_75
Author(s) : Ivanov AN , Lukachova LV , Evtugyn GA , Karyakina EE , Kiseleva SG , Budnikov HC , Orlov AV , Karpacheva GP , Karyakin AA
Ref : Bioelectrochemistry , 55 :75 , 2002
Abstract : Ivanov_2002_Bioelectrochemistry_55_75
ESTHER : Ivanov_2002_Bioelectrochemistry_55_75
PubMedSearch : Ivanov_2002_Bioelectrochemistry_55_75
PubMedID: 11786345

Title : Amperometric biosensors based on nafion coated screen-printed electrodes for the determination of cholinesterase inhibitors - Gogol_2000_Talanta_53_379
Author(s) : Gogol EV , Evtugyn GA , Marty JL , Budnikov HC , Winter VG
Ref : Talanta , 53 :379 , 2000
Abstract : Gogol_2000_Talanta_53_379
ESTHER : Gogol_2000_Talanta_53_379
PubMedSearch : Gogol_2000_Talanta_53_379
PubMedID: 18968123