Correa_2026_Auton.Neurosci_268_103496

Reference

Title : Cardiorespiratory and cardiac biomarker responses to five anesthetic regimens in rats - Correa_2026_Auton.Neurosci_268_103496
Author(s) : Correa LJ , Minassa VS , Jara BT , De Moura BAA , Batista TJ , Coitinho JB , do Bem D , Dos Santos L , Paton JFR , McBryde FD , Beijamini V , Felippe ISA , Sampaio KN
Ref : Auton Neurosci , 268 :103496 , 2026
Abstract :

General anesthetics enable invasive experimentation but can affect cardiovascular and respiratory physiology, biasing preclinical outcomes. We compared five anesthetic regimens in adult male Wistar rats, tribromoethanol (TBE, 250 mg/kg i.p.), chloral hydrate (CH, 400 mg/kg i.p.), ketamine-xylazine (KX, 80/10 mg/kg i.p.), thiopental (TP, 80 mg/kg i.p.), and isoflurane (ISO, 4% induction, 2% maintenance), to investigate integrated cardiorespiratory and biochemical markers. Femoral arterial catheterization allowed continuous blood pressure (BP) and derived heart rate (HR) recordings, while ventilation was assessed through pletysmography at baseline (awake), during induction, and early recovery phases of anesthesia. Variability was evaluated in the time and frequency domains, including HR, systolic blood pressure (SBP), and spontaneous baroreflex sensitivity. In an independent cohort of rats, butyrylcholinesterase (BChE), CK-MB, cTnI, and LDH were measured. Baseline BP was unchanged by TBE and TP, whereas all anesthetics affected HR. Minute ventilation and breathing frequency were reduced with all agents, while tidal volume decreased with KX and TBE only. LDH and cTnI were unaffected, BChE was reduced by KX, TBE, and ISO, and CK-MB increased with CH and KX. Variability analysis showed that all anesthetics depressed pulse-interval and SBP variability and shifted spectral power toward higher frequencies, while baroreflex sensitivity and effectiveness were consistently reduced. During early recovery, KX and TP restored most variability indices, whereas CH, TBE, and ISO showed continued suppression of these indices. These findings highlight distinct profiles of cardiovascular depression and biomarker responses across anesthetics and underscore the importance of accounting for autonomic variability when selecting different anesthetics in experimental protocols.

PubMedSearch : Correa_2026_Auton.Neurosci_268_103496
PubMedID: 42743852

Related information

Citations formats

Correa LJ, Minassa VS, Jara BT, De Moura BAA, Batista TJ, Coitinho JB, do Bem D, Dos Santos L, Paton JFR, McBryde FD, Beijamini V, Felippe ISA, Sampaio KN (2026)
Cardiorespiratory and cardiac biomarker responses to five anesthetic regimens in rats
Auton Neurosci 268 :103496

Correa LJ, Minassa VS, Jara BT, De Moura BAA, Batista TJ, Coitinho JB, do Bem D, Dos Santos L, Paton JFR, McBryde FD, Beijamini V, Felippe ISA, Sampaio KN (2026)
Auton Neurosci 268 :103496