Title : A continuous-flow, rapid-mixing, photolabeling technique applied to the acetylcholine receptor - Cox_1984_Anal.Biochem_136_476
Author(s) : Cox RN , Kaldany RR , Brandt PW , Ferren B , Hudson RA , Karlin A
Ref : Analytical Biochemistry , 136 :476 , 1984
Abstract :

A continuous-flow technique is described in which a photoaffinity label, membrane rich in acetylcholine receptor, and various effectors are rapidly mixed, passed through a delay tube, through a tube in which they are irradiated, and are collected in a tube containing quencher. Delay times as short as 20 ms between mixing and photolysis are achievable. Because the flow is continuous, milliliter volumes of membrane can be labeled in a single run, which is convenient for the analysis of both the functional effects and sites of photolabeling. Using this technique, we have found that receptor in its transitory, active state, in which the channel is open, is more susceptible to photolabeling by the noncompetitive inhibitor analog [3H] quinacrine azide than is receptor in either its resting or desensitized states, in which the channel is closed. This technique should prove generally useful for the photolabeling of transient conformational states of macromolecules.

PubMedSearch : Cox_1984_Anal.Biochem_136_476
PubMedID: 6721146

Related information

Citations formats

Cox RN, Kaldany RR, Brandt PW, Ferren B, Hudson RA, Karlin A (1984)
A continuous-flow, rapid-mixing, photolabeling technique applied to the acetylcholine receptor
Analytical Biochemistry 136 :476

Cox RN, Kaldany RR, Brandt PW, Ferren B, Hudson RA, Karlin A (1984)
Analytical Biochemistry 136 :476