Dounin_2010_Anal.Chim.Acta_669_63

Reference

Title : Disposable electrochemical printed gold chips for the analysis of acetylcholinesterase inhibition - Dounin_2010_Anal.Chim.Acta_669_63
Author(s) : Dounin V , Veloso AJ , Schulze H , Bachmann TT , Kerman K
Ref : Anal Chim Acta , 669 :63 , 2010
Abstract :

The detection of trace levels of paraoxon and carbofuran was achieved utilizing differential pulse voltammetry (DPV) on gold disposable electrochemical printed (DEP) chips. The nanostructured gold surface of the chips enables highly sensitive oxidation of the thiocholine (TCh) product even in the absence of costly surface modifications. The inhibition of AChE activity at varying insecticide concentrations was detected with low detection limits of 10 ppb (36 nM) for paraoxon and 8 ppb (18 nM) for carbofuran. Fine-tuning of the experimental conditions will allow for the application of unmodified DEP gold chips for inexpensive on-field detection of AChE inhibition by various insecticides at or below the allowable concentrations set by European and North American regulation standards.

PubMedSearch : Dounin_2010_Anal.Chim.Acta_669_63
PubMedID: 20510904

Related information

Citations formats

Dounin V, Veloso AJ, Schulze H, Bachmann TT, Kerman K (2010)
Disposable electrochemical printed gold chips for the analysis of acetylcholinesterase inhibition
Anal Chim Acta 669 :63

Dounin V, Veloso AJ, Schulze H, Bachmann TT, Kerman K (2010)
Anal Chim Acta 669 :63