| Title : Agreement of serum Spec cPL with the 1,2-o-dilauryl-rac-glycero glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay and with pancreatic ultrasonography in dogs with suspected pancreatitis - Kook_2014_J.Vet.Intern.Med_28_863 |
| Author(s) : Kook PH , Kohler N , Hartnack S , Riond B , Reusch CE |
| Ref : J Vet Intern Med , 28 :863 , 2014 |
|
Abstract :
BACKGROUND: Spec cPL is the most sensitive and specific test for diagnosing pancreatitis in dogs. Its results have not been compared to those of the 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay or those of abdominal ultrasonography. OBJECTIVES: To investigate agreement of Spec cPL with DGGR lipase activity and pancreatic ultrasonography in dogs with suspected pancreatitis. ANIMALS: One hundred and forty-two dogs. METHODS: DGGR lipase activity (reference range, 24-108 U/L) and Spec cPL were measured using the same sample. The time interval between ultrasonography and lipase determinations was <24 hours. The agreement of the 2 lipase assays at different cutoffs and the agreement between pancreatic ultrasonography and the 2 tests were assessed using Cohen's kappa coefficient (kappa). RESULTS: DGGR lipase (>108, >216 U/L) and Spec cPL (>200 g/L) had kappa values of 0.79 (95% confidence interval [CI], 0.69-0.9) and 0.70 (CI, 0.58-0.82). DGGR lipase (>108, >216 U/L) and Spec cPL (>400 g/L) had kappa values of 0.55 (CI, 0.43-0.67) and kappa of 0.80 (CI, 0.71-0.9). An ultrasonographic diagnosis of pancreatitis and DGGR lipase (>108, >216 U/L) had kappa values of 0.29 (CI, 0.14-0.44) and 0.35 (CI, 0.18-0.52). Ultrasonographically diagnosed pancreatitis and Spec cPL (>200, >400 g/L) had kappa values of 0.25 (CI, 0.08-0.41) and 0.27 (CI, 0.09-0.45). CONCLUSIONS AND CLINICAL IMPORTANCE: Although both lipase assays showed high agreement, agreement between ultrasonography and lipase assays results was only fair. Because lipase results are deemed more accurate, ultrasonography results should be interpreted carefully. |
| PubMedSearch : Kook_2014_J.Vet.Intern.Med_28_863 |
| PubMedID: 24597630 |
| Substrate | DGGR |
Kook PH, Kohler N, Hartnack S, Riond B, Reusch CE (2014)
Agreement of serum Spec cPL with the 1,2-o-dilauryl-rac-glycero glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay and with pancreatic ultrasonography in dogs with suspected pancreatitis
J Vet Intern Med
28 :863
Kook PH, Kohler N, Hartnack S, Riond B, Reusch CE (2014)
J Vet Intern Med
28 :863