Title : Agreement of serum Spec cPL with the 1,2-o-dilauryl-rac-glycero glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay and with pancreatic ultrasonography in dogs with suspected pancreatitis - Kook_2014_J.Vet.Intern.Med_28_863
Author(s) : Kook PH , Kohler N , Hartnack S , Riond B , Reusch CE
Ref : J Vet Intern Med , 28 :863 , 2014
Abstract :

BACKGROUND: Spec cPL is the most sensitive and specific test for diagnosing pancreatitis in dogs. Its results have not been compared to those of the 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay or those of abdominal ultrasonography. OBJECTIVES: To investigate agreement of Spec cPL with DGGR lipase activity and pancreatic ultrasonography in dogs with suspected pancreatitis. ANIMALS: One hundred and forty-two dogs. METHODS: DGGR lipase activity (reference range, 24-108 U/L) and Spec cPL were measured using the same sample. The time interval between ultrasonography and lipase determinations was <24 hours. The agreement of the 2 lipase assays at different cutoffs and the agreement between pancreatic ultrasonography and the 2 tests were assessed using Cohen's kappa coefficient (kappa). RESULTS: DGGR lipase (>108, >216 U/L) and Spec cPL (>200 g/L) had kappa values of 0.79 (95% confidence interval [CI], 0.69-0.9) and 0.70 (CI, 0.58-0.82). DGGR lipase (>108, >216 U/L) and Spec cPL (>400 g/L) had kappa values of 0.55 (CI, 0.43-0.67) and kappa of 0.80 (CI, 0.71-0.9). An ultrasonographic diagnosis of pancreatitis and DGGR lipase (>108, >216 U/L) had kappa values of 0.29 (CI, 0.14-0.44) and 0.35 (CI, 0.18-0.52). Ultrasonographically diagnosed pancreatitis and Spec cPL (>200, >400 g/L) had kappa values of 0.25 (CI, 0.08-0.41) and 0.27 (CI, 0.09-0.45). CONCLUSIONS AND CLINICAL IMPORTANCE: Although both lipase assays showed high agreement, agreement between ultrasonography and lipase assays results was only fair. Because lipase results are deemed more accurate, ultrasonography results should be interpreted carefully.

PubMedSearch : Kook_2014_J.Vet.Intern.Med_28_863
PubMedID: 24597630

Related information

Substrate DGGR

Citations formats

Kook PH, Kohler N, Hartnack S, Riond B, Reusch CE (2014)
Agreement of serum Spec cPL with the 1,2-o-dilauryl-rac-glycero glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay and with pancreatic ultrasonography in dogs with suspected pancreatitis
J Vet Intern Med 28 :863

Kook PH, Kohler N, Hartnack S, Riond B, Reusch CE (2014)
J Vet Intern Med 28 :863