Title : Simultaneous determination of donepezil (aricept) enantiomers in human plasma by liquid chromatography-electrospray tandem mass spectrometry - Matsui_1999_J.Chromatogr.B.Biomed.Sci.Appl_729_147 |
Author(s) : Matsui K , Oda Y , Nakata H , Yoshimura T |
Ref : Journal of Chromatography B Biomed Sci Appl , 729 :147 , 1999 |
Abstract :
A rapid, sensitive and enantioselective LC-MS-MS method using deuterium-labeled internal standard was developed and evaluated for the simultaneous quantitative determination of donepezil enantiomers in human plasma without interconversion during clean-up process and measurement. The use of an avidin column allowed the separation of donepezil enantiomers, which were specifically detected by MS-MS without interference from its metabolites and plasma constituents. Evaluation of this assay method shows that samples can be assayed with acceptable accuracy and precision within the range from 0.0206 ng/ml to 51.6 ng/ml for both R-donepezil and S-donepezil. This analytical method was applied to the simultaneous quantitation of donepezil enantiomers in human plasma. |
PubMedSearch : Matsui_1999_J.Chromatogr.B.Biomed.Sci.Appl_729_147 |
PubMedID: 10410937 |
Matsui K, Oda Y, Nakata H, Yoshimura T (1999)
Simultaneous determination of donepezil (aricept) enantiomers in human plasma by liquid chromatography-electrospray tandem mass spectrometry
Journal of Chromatography B Biomed Sci Appl
729 :147
Matsui K, Oda Y, Nakata H, Yoshimura T (1999)
Journal of Chromatography B Biomed Sci Appl
729 :147