Title : A high-performance liquid chromatographic assay for HI-6 oxime in plasma - McCluskey_1990_J.Analyt.Toxico_14_239
Author(s) : McCluskey MP , Clark CR , Talbot BG , Green MD , Lukey BJ
Ref : Journal of Analytical Toxicology , 14 :239 , 1990
Abstract :

A high-performance liquid chromatographic (HPLC) assay was developed to determine HI-6 (1-(2-hydroxyiminomethyl-1-pyridinio-3-(4-carbamoyl-1-py ridiniol-2-oxapropane dichloride)) concentrations in small volumes of plasma. A 100-microL plasma sample added to 900 microL of distilled water was microfiltered. Filtrate (200 microL) was injected onto an HPLC instrument containing a 100-microL sample loop, a C18 column, and an ultraviolet (UV) wavelength detector. Limit of sensitivity for HI-6 was 2.5 micrograms/mL. Extraction of efficiency (n = 12) at 10 and 100 micrograms HI-6/mL plasma was 69.4 +/- 6.6% (SD) and 81.5 +/- 2.0% (SD), respectively. Protein-plasma binding of HI-6 did not occur. HI-6 was stable when frozen at -20 degrees C for up to 10 days (0.025 less than p less than 0.05). Correlation coefficients representing standard curve linearity ranged from 0.9986 to 0.9999 (n = 6). Within-day and between-day coefficients of variation (n = 6) for unknown samples ranged from 4.4 to 8.3% and 5.8 to 17.1%, respectively. Bias of unknown samples ranged from -10.5 to 5.7%. The method's sensitivity, accuracy, and precision indicate that it can be used to accurately measure HI-6 concentrations in 100 microL of plasma.

PubMedSearch : McCluskey_1990_J.Analyt.Toxico_14_239
PubMedID: 2395347

Related information

Citations formats

McCluskey MP, Clark CR, Talbot BG, Green MD, Lukey BJ (1990)
A high-performance liquid chromatographic assay for HI-6 oxime in plasma
Journal of Analytical Toxicology 14 :239

McCluskey MP, Clark CR, Talbot BG, Green MD, Lukey BJ (1990)
Journal of Analytical Toxicology 14 :239