| Title : Cyclic voltammetric acetylcholinesterase biosensor for the detection of captan in apple samples with the aid of chemometrics - Nesakumar_2015_Anal.Bioanal.Chem_407_4863 |
| Author(s) : Nesakumar N , Sethuraman S , Krishnan UM , Rayappan JB |
| Ref : Anal Bioanal Chem , 407 :4863 , 2015 |
|
Abstract :
The presence of captan residues in apples shows high toxicity, which often causes eye and skin irritation, dermatitis, conjunctivitis, and vomiting in humans. In this context, an electrochemical biosensor based on acetylcholinesterase (AChE) immobilized on a ZnO nanorod interface has been proposed. In this work, Hill, dose-response, and first-, second-, and third-order polynomial regression models were successfully applied and the prediction ability of these models was tested with the use of current density obtained from the cyclic voltammograms of appropriate captan solutions. The Pt/ZnO/AChE bioelectrode showed a high sensitivity of 0.538 muA cm(-2) muM(-1) in the linear range from 0.05 to 25.0 muM with a limit of detection of 107 nM. The recovery results were observed between 98.4 and 102.4 % from the apple sample. This work provides a new promising tool for the detection of captan in apple samples. |
| PubMedSearch : Nesakumar_2015_Anal.Bioanal.Chem_407_4863 |
| PubMedID: 25895947 |
Nesakumar N, Sethuraman S, Krishnan UM, Rayappan JB (2015)
Cyclic voltammetric acetylcholinesterase biosensor for the detection of captan in apple samples with the aid of chemometrics
Anal Bioanal Chem
407 :4863
Nesakumar N, Sethuraman S, Krishnan UM, Rayappan JB (2015)
Anal Bioanal Chem
407 :4863