Poenick_2014_Biosens.Bioelectron_53_370

Reference

Title : Comparative label-free monitoring of immunotoxin efficacy in 2D and 3D mamma carcinoma in vitro models by impedance spectroscopy - Poenick_2014_Biosens.Bioelectron_53_370
Author(s) : Poenick S , Jahnke HG , Eichler M , Frost S , Lilie H , Robitzki AA
Ref : Biosensors & Bioelectronics , 53 :370 , 2014
Abstract :

For selective killing of tumor cells, there are many novel and promising therapeutic approaches like immunotoxins. However, on the long way to clinical application, especially in vitro approved biologicals often fail due to loss of target sensitivity and efficacy in vivo. This is mostly explained with degradation or penetration disability in vivo. Although, these problems are well known, until today, there are no in vitro systems for reliable monitoring and quantification of therapeutic efficacy in 3D tumor models and the direct comparison to results from 2D models. In this context, we developed a combined label-free impedimetric monitoring system using our self-developed planar interdigital electrode arrays and our unique microcavity array technology. Therefore, we could demonstrate the time and concentration dependent monitoring and quantification of therapeutic efficacy in a 2D and 3D mamma carcinoma model. In detail, we synthesized a novel modular immunotoxin B3(dsFv)-PE38 (B3-PE38) in which the antibody fragment and the protein toxin are polyionic linked together. We compared the efficacy of the immunotoxin B3-PE38, the toxin E8C-PE38 (PE38) and the small molecule chemotherapeutic paclitaxel. The impedimetric screening revealed the highest cytotoxicity for the immunotoxin B3-PE38 in the 2D model. More strikingly, the immunotoxin efficacy was substantially higher in the 3D model when compared to PE38 and paclitaxel even though having a considerably lower penetration capability than paclitaxel. So our novel impedimetric monitoring system offers the comparative efficacy quantification of novel therapeutics in 2D and 3D in vitro tumor models.

PubMedSearch : Poenick_2014_Biosens.Bioelectron_53_370
PubMedID: 24184957

Related information

Citations formats

Poenick S, Jahnke HG, Eichler M, Frost S, Lilie H, Robitzki AA (2014)
Comparative label-free monitoring of immunotoxin efficacy in 2D and 3D mamma carcinoma in vitro models by impedance spectroscopy
Biosensors & Bioelectronics 53 :370

Poenick S, Jahnke HG, Eichler M, Frost S, Lilie H, Robitzki AA (2014)
Biosensors & Bioelectronics 53 :370