Title : Poly(ethylene glycol) hydrogel-encapsulated fluorophore-enzyme conjugates for direct detection of organophosphorus neurotoxins - Russell_1999_Anal.Chem_71_4909 |
Author(s) : Russell RJ , Pishko MV , Simonian AL , Wild JR |
Ref : Analytical Chemistry , 71 :4909 , 1999 |
Abstract :
A simple approach is described for preparing poly-(ethylene glycol) hydrogel materials with encapsulated seminapthofluorescein (SNAFL)-organophosphorus hydrolase enzyme conjugates. Direct determination of enzyme-catalyzed neurotoxin hydrolysis is provided by the self-referencing, pH-sensitive dye SNAFL-1, whose emission spectrum changes at lambda = 550 in response to pH. Using spectrofluorimetry and paraoxon as a model organophosphate, paraoxon concentrations as low as 8 x 10(-7) M could be readily detected. On the basis of the signal-to-noise ratio, a detection limit of 16 nM was determined. The materials demonstrated high stability against enzyme-denaturing, leaching, and photobleaching when stored under ambient conditions. |
PubMedSearch : Russell_1999_Anal.Chem_71_4909 |
PubMedID: 10565282 |
Russell RJ, Pishko MV, Simonian AL, Wild JR (1999)
Poly(ethylene glycol) hydrogel-encapsulated fluorophore-enzyme conjugates for direct detection of organophosphorus neurotoxins
Analytical Chemistry
71 :4909
Russell RJ, Pishko MV, Simonian AL, Wild JR (1999)
Analytical Chemistry
71 :4909