Schuvailo_2005_Biosens.Bioelectron_21_87

Reference

Title : Carbon fibre-based microbiosensors for in vivo measurements of acetylcholine and choline - Schuvailo_2005_Biosens.Bioelectron_21_87
Author(s) : Schuvailo ON , Dzyadevych SV , El'skaya AV , Gautier-Sauvigne S , Csoregi E , Cespuglio R , Soldatkin AP
Ref : Biosensors & Bioelectronics , 21 :87 , 2005
Abstract :

This report describes technical improvements to the manufacture of a carbon fibre electrode for the stable and sensitive detection of H2O2 (detection limit at 0.5 microM). This electrode was also modified through the co-immobilisation of acetylcholinesterase (AChE) and/or choline oxidase (ChOx) in a bovine serum albumin (BSA) membrane for the development of a sensor for in vivo measurements of acetylcholine and choline. Amperometric measurements were performed using a conventional three-electrode system forming part of a flow-injection set-up at an applied potential of 800-1100 mV relative to an Ag/AgCl reference electrode. The optimised biosensor obtained was reproducible and stable, and exhibited a detection limit of 1 microM for both acetylcholine and choline. However, due to the high operating potential used, the biosensor was prone to substantial interference from other electroactive compounds, such as ascorbic acid. Therefore, in a further step, a mediated electron transfer approach was used that incorporated horseradish peroxidase into an osmium-based redox hydrogel layered onto the active surface of the electrode. Afterwards, a Nafion layer and a coating containing AChE and/or ChOx co-immobilised in a BSA membrane were successively deposited. This procedure further increased the selectivity of the biosensor, when operated in the same flow-injection system but at an applied potential of -50 mV relative to an Ag/AgCl reference electrode. The sensor exhibited good selectivity and a high sensitivity over a concentration range (0.3-100 microM) suitable for the measurement of choline and acetylcholine in vivo.

PubMedSearch : Schuvailo_2005_Biosens.Bioelectron_21_87
PubMedID: 15967355

Related information

Citations formats

Schuvailo ON, Dzyadevych SV, El'skaya AV, Gautier-Sauvigne S, Csoregi E, Cespuglio R, Soldatkin AP (2005)
Carbon fibre-based microbiosensors for in vivo measurements of acetylcholine and choline
Biosensors & Bioelectronics 21 :87

Schuvailo ON, Dzyadevych SV, El'skaya AV, Gautier-Sauvigne S, Csoregi E, Cespuglio R, Soldatkin AP (2005)
Biosensors & Bioelectronics 21 :87