Teiber_2013_Clin.Chem_59_1251

Reference

Title : Methods for Measuring Serum Activity Levels of the 192 Q and R Isoenzymes of Paraoxonase 1 in QR Heterozygous Individuals - Teiber_2013_Clin.Chem_59_1251
Author(s) : Teiber JF , Kramer GL , Haley RW
Ref : Clinical Chemistry , 59 :1251 , 2013
Abstract :

BACKGROUND: Paraoxonase 1 (PON1), an esterase that hydrolyzes toxic organophosphates and has antioxidative and antiatherogenic properties, contains a common polymorphism at position 192: glutamine (Q) or arginine (R). The Q and R isoenzymes exhibit different physical and protective properties. We describe 2 methods for quantifying their serum activity levels.
METHODS: We measured serum hydrolytic activity with paraoxon [paraoxonase (PXN) activity], phenylacetate [arylesterase (AE) activity], and diazoxon [diazoxonase (DZN) activity] with standard automated assays. We determined PON1 Q192R genotypes with PCR and Q192R phenotypes using the PXN/AE and PXN/DZN ratios. Interpolation equations were empirically derived to predict the percentage of total PON1 hydrolytic activity due to the Q isoenzyme (%Q) from the PXN/AE and PXN/DZN ratios; %R is 100 - %Q. We estimated Q and R isoenzyme activity levels in sera from 2095 veterans by multiplying AE activity, a measure of total PON1 hydrolytic activity, by %Q and %R.
RESULTS: In all 2095 samples, the PXN/AE and PXN/DZN ratios predicted Q192R phenotypes with nearly identical accuracy (kappa = 0.997). In the 925 QR heterozygotes, the 2 interpolation methods predicted Q and R isoenzyme activity levels with excellent agreement (intraclass correlation 0.94). After excluding a few genotype/phenotype-discordant samples, the percentage of total PON1 activity due to the Q isoenzyme ranged from 22% to 70%.
CONCLUSIONS: These new interpolation methods allow accurate estimation of PON1 192 Q and R isoenzyme activity levels, increasing specificity and power for studying susceptibility to disease.

PubMedSearch : Teiber_2013_Clin.Chem_59_1251
PubMedID: 23894162

Related information

Citations formats

Teiber JF, Kramer GL, Haley RW (2013)
Methods for Measuring Serum Activity Levels of the 192 Q and R Isoenzymes of Paraoxonase 1 in QR Heterozygous Individuals
Clinical Chemistry 59 :1251

Teiber JF, Kramer GL, Haley RW (2013)
Clinical Chemistry 59 :1251