| Title : The potential utility of [(68) Ga]Ga-DOTA-FAPI-04 as a novel broad-spectrum oncological and non-oncological imaging agent-comparison with [(18)F]FDG - Lan_2022_Eur.J.Nucl.Med.Mol.Imaging_49_963 |
| Author(s) : Lan L , Liu H , Wang Y , Deng J , Peng D , Feng Y , Wang L , Chen Y , Qiu L |
| Ref : Eur J Nucl Med Mol Imaging , 49 :963 , 2022 |
|
Abstract :
PURPOSE: This study aimed to compare the detection performance of [(68) Ga]Ga-DOTA-FAPI-04 and [(18)F]FDG PET/CT in the patients with various oncological and non-oncological lesions. METHODS: A total of 123 patients underwent contemporaneous [(68) Ga]Ga-DOTA-FAPI-04 and [(18)F]FDG PET/CT were included in this prospective study. The maximum standard uptake value (SUVmax) was measured to compare oncological and non-oncological lesion uptake. The sensitivity, specificity, predictive values, and accuracy of [(18)F]FDG and [(68) Ga]Ga-DOTA-FAPI-04 PET/CT for detecting primary, metastatic, and non-oncological lesions were calculated and compared to evaluate the detection efficacy. RESULTS: The study subjects consisted of 123 patients (69 men and 54 women; mean age 56.11 +/- 11.94 years). Among the 102 patients with either newly diagnosed (82 patients) or previously treated solid tumor (20 patients), a total of 88 solid primary malignant tumors in 84/102 patients were detected. Two patients had two primary tumors each and 1 patient had three primary tumors. Among them, 58/102 and 43/102 patients had nodal (376 lesions) and distant metastases (406 lesions), respectively. Eight patients had hematological neoplasm. No malignant oncological diseases were detected in the remaining 13 patients. A total of 145 non-oncological lesions and benign tumors in 52/123 patients were detected incidentally. [(68) Ga]Ga-DOTA-FAPI-04 PET/CT demonstrated a significantly higher uptake and detection rate for the primary (SUVmax 10.98 +/- 5.83 vs. 8.36 +/- 6.43, p < 0.001; sensitivity 97.67 vs. 84.89%; and accuracy 96.59 vs. 82.95%, X(2) = 0.538, p = 0.021), nodal (SUVmax 10.50 +/- 5.98 vs. 8.20 +/- 6.29, p = 0.011; sensitivity 97.59 vs. 84.72%; and accuracy 97.34 vs. 84.31%, X(2) = 2.067, p < 0.001), and distant metastatic lesions (SUVmax 9.64 +/- 6.45 vs. 6.74 +/- 4.83; p < 0.001; sensitivity 98.01 vs. 65.59%; and accuracy 97.04 vs. 65.51%, X(2) = 4.897, p < 0.001) of solid tumor than did [(18)F]FDG PET/CT. [(68) Ga]Ga-DOTA-FAPI-04 PET/CT demonstrated a lower activity (SUVmax: 6.84 +/- 4.67 vs. 13.09 +/- 7.29, p < 0.001) and detection rate (sensitivity 50.65 vs. 96.75%, and accuracy 51.28 vs. 95.51%, X(2) = 5.166, p < 0.001) for multiple myeloma and lymphoma compared to [(18)F]FDG PET/CT. [(68) Ga]Ga-DOTA-FAPI-04 and [(18)F]FDG PET/CT PET/CT demonstrated a comparative activity (SUVmax 6.40 +/- 3.95 vs. 5.74 +/- 15.78, p = 0.729) and detection efficacy (sensitivity 86.52 vs. 72.34%, and accuracy 84.83 vs. 72.41%, X(2) = 9.460, p = 0.007) for non-oncological lesion and benign tumor detection. CONCLUSIONS: Except for myeloma and lymphoma, [(68) Ga]Ga-DOTA-FAPI-04 PET/CT showed a superior detection efficacy for detecting various primary and metastatic lesions than [(18)F]FDG PET/CT. A comparative detection utility for non-oncological lesion was obtained with both tracers. [(68) Ga]Ga-DOTA-FAPI-04 could be used as a broad-spectrum tumor and inflammatory imaging agent in the clinical especially for various solid tumors and non-oncological lesions. |
| PubMedSearch : Lan_2022_Eur.J.Nucl.Med.Mol.Imaging_49_963 |
| PubMedID: 34410435 |
| Inhibitor | FAPI-04 |
Lan L, Liu H, Wang Y, Deng J, Peng D, Feng Y, Wang L, Chen Y, Qiu L (2022)
The potential utility of [(68) Ga]Ga-DOTA-FAPI-04 as a novel broad-spectrum oncological and non-oncological imaging agent-comparison with [(18)F]FDG
Eur J Nucl Med Mol Imaging
49 :963
Lan L, Liu H, Wang Y, Deng J, Peng D, Feng Y, Wang L, Chen Y, Qiu L (2022)
Eur J Nucl Med Mol Imaging
49 :963