Lenigk_2000_Biosens.Bioelectron_15_541

Reference

Title : Enzyme biosensor for studying therapeutics of Alzheimer's disease - Lenigk_2000_Biosens.Bioelectron_15_541
Author(s) : Lenigk R , Lam E , Lai A , Wang H , Han Y , Carlier PR , Renneberg R
Ref : Biosensors & Bioelectronics , 15 :541 , 2000
Abstract :

An electrochemical method for the investigation and comparison of anti-Alzheimer medications that is based on the inhibition of the acetylcholinesterase is presented. The developed amperometric biosensor determines the in-vitro inhibition of the acetylcholinesterase that is co-immobilized with choline oxidase on the working electrode surface of a three-electrode system using gel entrapment. The sensor has been applied to determine the IC50 values of two known and one newly developed Alzheimer remedy. A simultaneous measurement with the photometric standard method shows the applicability of our method for fast drug screening.

PubMedSearch : Lenigk_2000_Biosens.Bioelectron_15_541
PubMedID: 11419651

Related information

Citations formats

Lenigk R, Lam E, Lai A, Wang H, Han Y, Carlier PR, Renneberg R (2000)
Enzyme biosensor for studying therapeutics of Alzheimer's disease
Biosensors & Bioelectronics 15 :541

Lenigk R, Lam E, Lai A, Wang H, Han Y, Carlier PR, Renneberg R (2000)
Biosensors & Bioelectronics 15 :541