Title : Bioelectrochemical analysis of neuropathy target esterase activity in blood - Sigolaeva_2001_Anal.Biochem_290_1
Author(s) : Sigolaeva LV , Makower A , Eremenko AV , Makhaeva GF , Malygin VV , Kurochkin IN , Scheller FW
Ref : Analytical Biochemistry , 290 :1 , 2001
Abstract :

Bioelectrochemical analysis of neuropathy target esterase (NTE) and its inhibitors is based on the combination of the NTE-catalyzed hydrolysis of phenyl valerate and phenol detection by a tyrosinase carbon-paste electrode. The use of the tyrosinase electrode improves 10-fold the sensitivity of NTE detection in comparison with a spectrophotometric method. The tyrosinase electrode was found to be suitable for measurements in whole human blood where spectrophotometric detection is considerably restricted. The specificity of NTE in blood for mipafox and di-2-propyl phosphorofluoridate was close to that for neuronal NTE. The NTE-like activity in blood was determined to be 0.19 +/- 0.02 nmol/min/mg of protein.

PubMedSearch : Sigolaeva_2001_Anal.Biochem_290_1
PubMedID: 11180931

Related information

Citations formats

Sigolaeva LV, Makower A, Eremenko AV, Makhaeva GF, Malygin VV, Kurochkin IN, Scheller FW (2001)
Bioelectrochemical analysis of neuropathy target esterase activity in blood
Analytical Biochemistry 290 :1

Sigolaeva LV, Makower A, Eremenko AV, Makhaeva GF, Malygin VV, Kurochkin IN, Scheller FW (2001)
Analytical Biochemistry 290 :1