Matsui_1995_J.Chromatogr.A_694_209

Reference

Title : Direct determination of E2020 enantiomers in plasma by liquid chromatography-mass spectrometry and column-switching techniques - Matsui_1995_J.Chromatogr.A_694_209
Author(s) : Matsui K , Oda Y , Ohe H , Tanaka S , Asakawa N
Ref : Journal of Chromatography A , 694 :209 , 1995
Abstract : High-performance liquid chromatography with column switching and mass spectrometry (MS) was applied to the on-line determination and resolution of the enantiomers of E2020 (acetylcholinesterase inhibitor) in plasma. This system employs two avidin columns and fast atom bombardment (FAB)-MS. A plasma sample was injected directly into an avidin trapping column (10 mm x 4.0 mm I.D.). The plasma protein was washed out from the trapping column immediately while E2020 was retained. After the column-switching procedure, E2020 was separated enantioselectivity in an avidin analytical column. The separated E2020 enantiomers were specifically detected by FAB-MS without interference from metabolites of E2020 and plasma constituents. The limit of quantification for each enantiomer of E2020 in plasma was 1.0 ng/ml and the intra- and inter-assay relative standard deviations for the method were less than 5.2%. The assay was validated for enantioselective pharmacokinetic studies in the dog.
ESTHER : Matsui_1995_J.Chromatogr.A_694_209
PubMedSearch : Matsui_1995_J.Chromatogr.A_694_209
PubMedID: 7719466

Related information

Citations formats

Matsui K, Oda Y, Ohe H, Tanaka S, Asakawa N (1995)
Direct determination of E2020 enantiomers in plasma by liquid chromatography-mass spectrometry and column-switching techniques
Journal of Chromatography A 694 :209

Matsui K, Oda Y, Ohe H, Tanaka S, Asakawa N (1995)
Journal of Chromatography A 694 :209

Array
(
    [id] => 47347
    [paper] => Matsui_1995_J.Chromatogr.A_694_209
    [author] => Matsui K || Oda Y || Ohe H || Tanaka S || Asakawa N
    [year] => 1995
    [title] => Direct determination of E2020 enantiomers in plasma by liquid chromatography-mass spectrometry and column-switching techniques
    [journal] => Journal of Chromatography A
    [volume] => 694
    [page] => 209
    [medline] => 7719466
    [abstract] => Matsui_1995_J.Chromatogr.A_694_209
    [kin_reference] => 
    [mutation] => 
    [kinetic_parameter] => 
    [inhibitor] => Aricept~Donepezil~E2020
    [kin_value] => 
    [substrate] => 
    [gene_locus] => Array
        (
        )

    [family] => 
    [interact_gene_locus] => 
    [xenobiotic_sensitivity] => 
    [news] => 
    [likid_reference] => 
    [lip_reference] => 
    [gene_locus_frgt] => 
    [structure] => 
    [comment] => 
    [chemical] => 
    [arpigny_jaeger] => 
    [reactivator] => 
    [disease] => 
    [enzyme] => 
    [risk_factor] => 
    [tissue] => 
    [sub_tissue] => 
    [activity] => 
    [specific_activity] => 
    [disease_by_interaction] => 
    [abstract_text] => Array
        (
            [id] => 254932
            [longtext] => Matsui_1995_J.Chromatogr.A_694_209
            [content] => High-performance liquid chromatography with column switching and mass spectrometry (MS) was applied to the on-line determination and resolution of the enantiomers of E2020 (acetylcholinesterase inhibitor) in plasma. This system employs two avidin columns and fast atom bombardment (FAB)-MS. A plasma sample was injected directly into an avidin trapping column (10 mm x 4.0 mm I.D.). The plasma protein was washed out from the trapping column immediately while E2020 was retained. After the column-switching procedure, E2020 was separated enantioselectivity in an avidin analytical column. The separated E2020 enantiomers were specifically detected by FAB-MS without interference from metabolites of E2020 and plasma constituents. The limit of quantification for each enantiomer of E2020 in plasma was 1.0 ng/ml and the intra- and inter-assay relative standard deviations for the method were less than 5.2%. The assay was validated for enantioselective pharmacokinetic studies in the dog.
        )

)